All size fittings available.
Fire hydrant connection sizes.
Connection takes just 1 4 turn to connect or disconnect.
Dry hydrants are pipes connected to unpressurized water sources like lakes or ponds the choice of male or female threads varies from place to place.
4 1 2 m v o.
The great baltimore fire of 1904 which destroyed more than 1 500 buildings in baltimore md and the 1991 oakland hills fire where incompatible hose and fire hydrant couplings delayed a fight against an oakland ca blaze that killed 25 people.
Harrington integral hydrant storz permits firefighters to connect fire hose to your hydrant in seconds.
They are commonly used to help firefighters be prepared and save time in emergency response and firefighting applications.
150 mm for fire boat connections.
19 mm nominal diameter fitted with garden hose couplings.
Two 2 1 2 inch 65 mm side outlets and a single 4 1 2 inch 115 mm or 6 inch 150 mm pumper outlet.
Pipe size shall be a minimum of 6 in.
A 1 1 1 some fire fighting organizations use small hose less than 3 4 in.
Fire hydrant having barrel thread dimensions of 8 250 o d.
Fire hose nozzles have female inlets that connect to male ended fire hoses.
Hydrants have 5 1 4 bonnets upper barrels safety flanges and lower barrels and are marked 5 1 4 even though the main valve opening is 4 1 2.
The size and number of the outlets serve as one limit to the.
Harrington s is widely regarded as the most efficient available.
Fire hydrant connections carry hose pumper hose city nom.
The flange at the base of the hydrant is the point of connection for the hydrant to the rest of the barrel.
X 4 tpi threads per inch.
Fire hydrants have male threaded outlets or nozzles.
1 1 1 this standard gives the performance and requirements for new fire hose couplings and adapters with nominal sizes from 3 4 in.
For hydraulically calculated systems the pipe size shall be permitted to be less than 4 in.
Fdc stands for fire department connection.
100 mm for fire engine connections.
Seat ring removeable without removing lower barrel.
Pipe size shall be a minimum of 4 in.
This is a connection on the exterior of a commercial building where a responding fire department can attach a fire hose and pump water into the building s stand pipe system supplementing the water pressure to the buidling s sprinkler system.
19 mm through 8 in.
100 mm but not less than the largest riser.
Fire hose and hydrant adapters are fittings that securely connect fire hoses to nozzles hydrants fire trucks and other water sources.
A traditional dry barrel fire hydrant contains three outlets.
200 mm and the specifications for the screw thread connections on those couplings and adapters.